Public Key Infrastructure Home /
CAC Lab /
GDS-JEDS Lab /
PKE Lab /
PKI Lab
Acronyms /
Frequently Asked Questions /
Online Resources /
POCs /
Request for Information /
Terms and Definitions
Application Testing / External Certification Authority Testing / Online Certificate Status Protocol Responder Testing
JITC PKE Lab testing procedures:
- Download and review the PKE Master Test Plan (MTP), version 1.2, dated November 2001 from the online resources page.
- Download and review the PKE Application Requirements, version 1.0, dated 13 July 2000 from the online resources page.
- Download and review the Cignacom Solutions' Conformance Testing of Relying Party Client Certificate Path Processing Logic, version 1.07, dated 28 September 2001 from the online resources page.
- Download The Cignacom Solutions' Conformance Testing of Relying Party Client Certificate Path Processing Logic Certificates from the online resources page.
- Complete your internal testing using the Cignacom Solutions' Conformance Testing of Relying Party Client Certificate Path Processing Logic test suite.
NOTE: All level 1 and level 2 tests must pass, level 3 tests are for diagnostics.
- Request JITC-issued client certificates from the PKI Lab.
NOTE: You must request a JITC Valid, Revoked, and Expired certificate.
- If the application can support Common Access Cards (CACs) and if requested, we will test with JITC-issued CACs (Valid, Revoked, and Expired).
NOTE: The PKE Lab personnel can assist in you acquiring JITC-issued CACs.
- Once internal testing is complete, then download and prepare the PKE Application Assessment Worksheet (AAW) from the online resources page..
- Once the AAW is complete, submit the AAW to the JITC PKE Team.
- Once received the PKE Lab Manager will review the AAW. He will do one of two things:
- Respond to you with questions about your application.
- Assign a test engineer.
- Respond to you with questions about your application.
- Once a test engineer is assigned, the test engineer will contact you for more information (e.g. for software: Where to download it? and for Hardware: The test engineer will give you the shipping address.)
- Throughout the testing process the test engineer will be in constant contact with the technical POC listed on the AAW.
- Once completed testing, the test engineer will complete the JITC Certification documentation. The test engineer has 15 working days to deliver it to the Government Action Officer (AO).
- Once delivered to the AO, the PKE Lab can only assist in tracking the certification letter.
PKE - Application Status by Category